Firmata
The Firmata protocol is based on the MIDI protocol used for communicating with musical equipment.
It is also one of the most widely used protocols for communication with Arduino devices.
This driver is built to be compatible with the StandardFirmata Arduino Sketch which can be found here (Version last changed on August 17th, 2017)
Supported Operations
| Name | Value | Description |
|---|---|---|
write | Writing is only supported to digital addresses. | |
subscribe | Subscribing is supported for both digital and analog addresses. See note below. |
Neither the Go nor the Java driver reads; a board is driven and monitored, never polled.
| When subscribing to pins, these are configured to become read pins. When writing to digital pins, these are configured to become output pins. However, writing to pins for which a subscription exists, an exception will be thrown. In order to write to previously subscribed pins, all subscriptions for this have to be cancelled first. |
|---|
Connection String
firmata:serial://{comm-port}[?{options}]
firmata:tcp://{ip-address}[?{options}]serial is the default transport - the classic Firmata-over-UART path. tcp targets StandardFirmataWiFi / StandardFirmataEthernet style boards, and is also used as a fallback when the serial transport can’t open a socat-bridged PTY (as on macOS).
Connection String Options
Name
Type
Default Value
Required
Description
Name
Firmata
Code
firmata
Maven Dependency
<dependency>
<groupId>org.apache.plc4x</groupId>
<artifactId>plc4j-driver-firmata</artifactId>
<version>1.0.0</version>
</dependency>Default Transport
serial
Supported Transports
serialtcp
Config options:
request-timeout-ms
INT
10000
Maximum time (in milliseconds) to wait for the initial firmware-report reply during connection setup.
Transport config options:
serial
serial.baud-rate
INT
9600
Baud rate (bits per second)
serial.data-bits
INT
8
Number of data bits (5, 6, 7, or 8)
serial.stop-bits
INT
1
Number of stop bits (1 or 2)
serial.parity
STRING
none
Parity: none, odd, even, mark, space (case-insensitive)
serial.flow-control
STRING
none
Flow control: none, rts-cts, xon-xoff (case-insensitive)
serial.read-timeout-ms
INT
1000
Read timeout in milliseconds. 0 means blocking read.
serial.write-timeout-ms
INT
1000
Write timeout in milliseconds.
serial.dtr
BOOLEAN
false
Enable DTR (Data Terminal Ready) signal
serial.rts
BOOLEAN
false
Enable RTS (Request To Send) signal
serial.reuse-port
BOOLEAN
false
Reuse the underlying serial port across multiple transport instances. When true, instances with the same port will share a connection. This is useful for protocols where multiple logical connections share one serial port. Connections sharing a port must target distinct unit ids; Modbus RTU responses carry no transaction ids, so same-unit traffic from multiple connections cannot be told apart.
serial.interframe-delay
INT
0
Interframe delay in milliseconds for protocols that need spacing between messages. Applies to shared and dedicated ports; the gap is measured from the last write or received data.
tcp
tcp.connect-timeout-ms
INT
5000
Connection timeout in milliseconds.
tcp.read-timeout-ms
INT
0
Socket read timeout in milliseconds. 0 means no timeout.
tcp.write-timeout-ms
INT
0
Socket write timeout in milliseconds. 0 means no timeout.
tcp.no-delay
BOOLEAN
true
Enable TCP_NODELAY (disable Nagle’s algorithm).
tcp.keep-alive
BOOLEAN
false
Enable SO_KEEPALIVE.
tcp.send-buffer-size
INT
81920
Send buffer size in bytes. 0 uses system default.
tcp.receive-buffer-size
INT
81920
Receive buffer size in bytes. 0 uses system default.
tcp.local-address
STRING
Local address to bind to (optional). If not set, uses default.
tcp.local-port
INT
0
Local port to bind to (optional). 0 uses ephemeral port.
Tag Addresses
Addressing is implemented in Go and Java. Neither driver reads; a board is driven and monitored, never polled. See the protocol support matrix for what each implementation does.
Firmata addresses carry no type, so the brackets did not move when the notation was unified - and their meaning changed with nothing to reject. 3[4] used to mean four pins starting at pin 3; it now means one pin, the fifth. Rewrite these as 3[0..3]. |
|---|
General Format
A Firmata address always begins with a digital: or analog: prefix, naming which of the two address forms below applies. See Addressing arrays for the [{selection}] part shared by both.
The Java driver caps the pin number itself at 3 digits (0-999, FirmataTag.ADDRESS_PATTERN, \d{1,3}), and separately caps the address plus selection at the 256 pins the protocol can name on the wire (FirmataTag.PIN_COUNT). The Go driver’s ported pattern uses an unbounded \d+ for the pin number itself (plc4go/internal/firmata/TagHandler.go:38), so digital:1234 parses on the Go side and is rejected by Java - see the firmata entry in the Java/Go address divergence report for this restructure.
Binary Addresses
The full format for a digital address is:
digital:{start-address}[{selection}]:{special-config}The start-address is a plain integer. special-config can be used to configure the digital input pin to something else than INPUT; currently the only supported option is PULLUP, which configures the Arduino’s digital input pin to use its built-in pullup-resistor.
Both the [{selection}] and the :{special-config} parts are optional.
A normal Arduino Uno is equipped with 14 digital inputs: 0-13.
However in case of using the serial port (which will always be the case when using this driver), the pins 0 and 1 are the RX and TX pins of the serial port and can’t be used. |
|---|
Analog Addresses
The full format for an analog address is:
analog:{start-address}[{selection}]The start-address is a plain integer, and [{selection}] is optional.
A normal Arduino Uno is equipped with 6 analog inputs: 0-5.
Data Types
Firmata addresses carry no type suffix; the type is implied by which prefix is used. Digital addresses are always BOOL (FirmataTagDigital.getPlcValueType()); analog addresses are always INT (FirmataTagAnalog.getPlcValueType()).
Examples
digital:2
digital:5
digital:8[0..3]:PULLUP
digital:0[0..255]
analog:0
analog:3
analog:0[0..2]More Information
- Addressing arrays - the shared
[{selection}]syntax.